Cat6 Ethernet Cable

Cat6 Ethernet Cable

High performance Cat6 Ethernet Cable, 250MHz bandwidth for gigabit network. UTP/FTP/SFTP options, solid bare copper, PVC & LSZH jacket. Direct manufacturer, bulk supply for indoor structured cabling, IP camera and commercial network projects.
Send Inquiry
Description

Jiaxing Doublewin Cable Co., Ltd. is one of the most reliable manufacturers and suppliers of cat6 ethernet cable in China. If you're going to wholesale bulk cat6 ethernet cable made in China, welcome to get pricelist and free sample from our factory. All customized cables are with high quality and competitive price.

 

Cat6 Ethernet Cable - More Than Doubles the Bandwidth. The Spline Keeps It There.
 

Cat6 Ethernet Cable (also known as Cat6 LAN cable) is a high-performance twisted-pair network cable for structured indoor cabling. It features 4 pairs of twisted solid copper conductors, HDPE insulation and a cross separator to reduce crosstalk. It delivers 250MHz bandwidth, supporting stable 1Gbps transmission up to 100 meters and short-range 10Gbps networking. We manufacture UTP, FTP and SFTP Cat6 ethernet cable. Outer jacket options include PVC for general indoor use and LSZH for low-smoke, fire-safe building requirements. This cable is widely deployed in office networks, IP camera surveillance, commercial building wiring and data communication systems.

As a professional cable manufacturer, we provide bulk reels, custom cable printing and OEM packaging for distributors, system integrators and engineering contractors worldwide.

Key Features

• 250MHz bandwidth, supports Gigabit Ethernet

• Solid bare copper conductor for stable signal transmission

• Integrated cross divider to minimize near-end crosstalk

• Multiple constructions: UTP / FTP / SFTP available

• PVC or LSZH outer sheath for different indoor projects

• RoHS compliant, durable for long-term in-wall installation

Cat6 ethernet cable
 
Cat6 Ethernet Cable Technical Specifications

Cat6 Ethernet Cables deliver 250 MHz bandwidth and 1 Gbps speed, offered in U/UTP, F/UTP and SF/UTP for any indoor link.

Product Name Cat6 Ethernet Cable
AWG 23AWG or custom
Conductor Material CU / CCA
Wire Diameter 0.56/0.58mm
Shield UTP / FTP / SFTP
Jacket Material 1. PVC Jacket for Cat6 indoor cable
2. PE Single jacket for Cat6 outdoor cable
3. PVC + PE double jacket Cat6 outdoor cable
Color Different color is available
Operating Temperature -20 °C - +75 °C
Certification CE/ROHS/ISO9001
Fire Rating CMP/CMR/CM/CMG/CMX
Application PC/ADSL/Network Module Plate/Wall Socket/etc
Package 1000ft 305m per roll,or custom
Marking On Jacket Custom

     

Model Application Main Performance Structure Features Sheath Material

Cat6 U/UTP 

Indoor

Indoor horizontal cabling, LAN wiring 250MHz bandwidth, 1000Mbps, supports up to 5GBASE-T 23AWG oxygen-free copper, central cross separator, optimized crosstalk PVC / LSZH optional

Cat6 F/UTP

Indoor

Indoor cabling, moderate anti-interference 250MHz bandwidth, 1000Mbps Aluminum foil shielding + 23AWG copper conductor, reliable electrical performance PVC / LSZH
Cat 6 SF/UTP Indoor Indoor cabling, high EMI environments 250MHz bandwidth, 1000Mbps, strong anti-interference Double shielding (aluminum foil + braid), 23AWG copper PVC / LSZH
Cat 6 U/UTP Outdoor Outdoor LAN wiring, overhead, wall mounting 100MHz bandwidth, 1000Mbps 23AWG copper, central cross separator, unshielded PE outer jacket, waterproof & UV-resistant
Cat 6 F/UTP Outdoor Outdoor cabling, EMI protection 250MHz bandwidth, 1000Mbps Single aluminum foil shielding, 23AWG copper conductor PE + PVC double sheath
Cat 6 SF/UTP Outdoor Outdoor high-interference environments 250MHz bandwidth, 1000Mbps Double shielding (foil + braid), high EMI resistance PE + PVC double sheath, weatherproof

 

Cat6 cable
 

Cat6 network cable

CAT6 UTP cable
Cat6 FTP cable

 

 

   Cat6 Ethernet Cable - The Sweet Spot for New Structured Cabling

Ask any cabling installer what they put in a new building and the answer is Cat6 Ethernet cable. At 250 MHz it has twice the bandwidth of Cat5e, handles Gigabit Ethernet with generous headroom, supports PoE and PoE+ without heating issues, and avoids the Cat6a price premium that most offices do not need. Cat6 is the minimum category recommended by BICSI, the leading structured cabling association, and is the sweet spot where performance, cost and future-proofing meet. This page gives you the performance numbers, the shielding choices, the installation grades, and how Cat6 compares to Cat5e and Cat6a - so you can specify with confidence.

250 MHz

Twice the bandwidth of Cat5e (100 MHz).

1 Gbps · 100 m

Gigabit Ethernet with generous headroom.

PoE / PoE+

30 W per port - Wi-Fi APs, IP cameras.

UTP Standard

Unshielded is enough for most offices.

CM / CMR / CMP

Any installation grade available.

Global Standards

TIA/EIA-568-B.2-5, ISO/IEC 11801 Class E.

 

Cat6 vs Cat5e vs Cat6a - Why Cat6 Is the Sweet Spot

The three most common structured cabling categories sit on a cost/performance curve. Cat6 lands exactly where most new office installs need to be: enough bandwidth and headroom without paying for 10 Gbps that most offices will not use for a decade.

Cat5e

1 Gbps

100 MHz bandwidth

100 m · PoE+ max

• Cheapest option

• No headroom above Gigabit

• Budget retrofits only

Cat6 ★

1 Gbps

250 MHz bandwidth

100 m · PoE+ ready

• 2× Cat5e bandwidth

• Best headroom/cost ratio

• BICSI recommended minimum

Cat6A

10 Gbps

500 MHz bandwidth

100 m · PoE++ ready

• 10× data rate vs Cat6

• 50–70% cost premium

• Data centres, future-proofing

Parameter Cat5e Cat6 Cat6A
Bandwidth 100 MHz 250 MHz 500 MHz
Max data rate 1 Gbps 1 Gbps + headroom 10 Gbps
Max channel length 100 m 100 m 100 m
Conductor 24 AWG 23 or 24 AWG 23 AWG
NEXT @ 250 MHz Not specified ≥ 38.3 dB ≥ 38.3 dB
ACR @ 250 MHz Not specified ≥ 17.8 dB ≥ 18.0 dB
Insertion loss @ 250 MHz Not specified ≤ 21.4 dB ≤ 20.7 dB
PoE PoE & PoE+ PoE & PoE+ PoE & PoE+ & PoE++
Relative cost 100% ~120% ~180%

 

Rule of thumb
• Budget retrofit, existing Cat5 running → Cat5e only if you must
• New office install, best headroom/cost → Cat6 (recommended minimum)
• Data centre, PoE++, 10 Gbps future → Cat6a
• Save 50–70% vs Cat6A and still get 250 MHz headroom with Cat6

 Cat6 Ethernet Cable - UTP, FTP or SFTP?

Cat6 Ethernet cable does not require shielding to meet its 250 MHz performance specification - unlike Cat7 and Cat8, which are always shielded. But shielding still has a place where electromagnetic interference (EMI) is present.

Type Structure EMI Rejection When to Use
UTP 4 twisted pairs, no shield Low Standard offices, schools, most indoor installs
FTP Al foil overall + tinned Cu drain wire Medium Near power cables, machinery, broadcast, HVAC motors
SFTP Al foil + tinned Cu braid shield High Industrial, high EMI, data centres with power density

 

Important - Shield grounding

A shield only works if it is grounded at one end only (typically the patch panel / switch end). Grounding at both ends creates a ground loop that cancels the shielding. All our FTP and SFTP Cat6 Ethernet cables come with a tinned copper drain wire for proper grounding.

Cat6 SFTP cable

 

 
Your Brand on a Cat6 Reel
 

Custom jacket colour, print legend, length, packaging. RJ45 patch cord assemblies on request. NDA-protected private-label SKUs.

RFQ & Feasibility

Send spec, volume, destination. Feasibility, MOQ and pricing within 12 working hours.

 

Custom Sample

Custom-printed sample in your brand colour for your termination team to validate.

 

Production & QC

20–25 working days. Progress photos at copper draw, spline insert, sheath, final test.

 

Test, Pack & Ship

100% electrical test, export packing, docs (CI/PL/B/L/C/O/RoHS). Ships Shanghai/Ningbo.

 

Start Your OEM Project

FAQ

Q.What is Cat6 Ethernet cable?

Cat6 (Category 6) Ethernet cable is a twisted pair cable defined by TIA/EIA-568-B.2-5 and ISO/IEC 11801 Class E. It has a bandwidth of 250 MHz - twice the 100 MHz of Cat5e - and supports Gigabit Ethernet (1 Gbps) up to 100 m. Cat6 uses 23 AWG or 24 AWG solid copper conductors, a tighter twist than Cat5e to control crosstalk, and improved NEXT (near-end crosstalk) and ACR (attenuation-to-crosstalk ratio) specifications at 250 MHz. It is the recommended minimum category for all new structured cabling installations.

Q.What is the difference between Cat5e, Cat6 and Cat6A?

Cat5e has 100 MHz bandwidth and 1 Gbps up to 100 m, costing less but with no headroom above Gigabit. Cat6 has 250 MHz bandwidth, 1 Gbps up to 100 m, better NEXT/ACR at higher frequencies and more headroom for future protocols - it is the sweet spot for new office installs. Cat6a has 500 MHz bandwidth and 10 Gbps up to 100 m, but costs about 50–70% more than Cat6 and requires 23 AWG. Use Cat5e only for budget retrofits, Cat6 for most new offices, and Cat6A for data centres, PoE++ (60/95 W) and future 10 Gbps needs.

Q.Is Cat6 Ethernet cable shielded or unshielded?

Cat6 Ethernet cable is most commonly UTP (unshielded twisted pair), which is perfectly adequate for offices and environments without strong electromagnetic interference. FTP (foil shield with drain wire) and SFTP (foil plus braid shield) versions are also available for installations near machinery, power cables, broadcast equipment or industrial environments where EMI would otherwise degrade performance. Unlike Cat7 and Cat8, Cat6 does not require shielding to meet its performance specification.

Q.Is Cat6 Ethernet cable PoE ready?

Yes, Cat6 Ethernet cable is fully PoE and PoE+ ready. PoE (IEEE 802.3af, 15.4 W per port) and PoE+ (IEEE 802.3at, 30 W per port) work on Cat5e and above, and Cat6 is a reliable choice because its lower resistance and tighter twist keep the temperature rise well within the PoE limits. For PoE++ (60 W on 4-pair) and especially PoE++ (95 W), Cat6a is recommended because the higher power density generates more heat and Cat6a has better thermal margins.

Q.What is the difference between CM, CMR and CMP Cat6 cable?

CM is the general-purpose rating for horizontal concealed runs in wall cavities and floors, tested to UL 1685. CMR is the riser rating for vertical runs between floors in riser shafts, tested to the more severe UL 1666 riser flame test. CMP is the plenum rating for installation in air-handling plenum spaces above ceilings, tested to UL 910 Steiner tunnel for both flame spread and smoke density - it is the most restrictive and most expensive. Always match the cable rating to where it will run in the building code.

 

Q.Should I choose UTP, FTP or SFTP for Cat6?

For most office and campus LANs, UTP is enough - the spline does most of the crosstalk work. Pick FTP (overall foil) when the cable runs near mains power, lifts or motors. Pick SFTP (foil plus pair braiding) for data centres, server rooms and heavy EMI industrial floors. We make all three constructions.

 

 

 

 

 

modular-1
Specify Cat6. We'll Build It.

Send your spec, target volume and destination. Walter Chou or Rita Ding reply within 12 working hours with factory-direct pricing, lead time and a free sample offer - direct from the manufacturer.

Hot Tags: cat6 ethernet cable, China cat6 ethernet cable manufacturers, suppliers, factory

Send Inquiry