Jiaxing Doublewin Cable Co., Ltd. is one of the most reliable manufacturers and suppliers of cat6 lan cable in China. If you're going to wholesale bulk cat6 lan cable made in China, welcome to get pricelist and free sample from our factory. All customized cables are with high quality and competitive price.
Cat5e hits 100MHz. Cat6 more than doubles that to 250MHz by adding an internal plastic spline that physically separates the four twisted pairs. This spline reduces crosstalk, allowing Cat6 to support 10Gbps at longer distances than Cat5e. For most office, campus and small-data-centre LANs, Cat6 is the sweet spot: enough headroom for 10Gbps uplinks, full PoE support, and backward compatible with every Cat5e outlet you already own.
23AWG solid bare copper conductors
Thicker than Cat5e's 24AWG - lower DC resistance, better PoE thermal headroom.
Four individually twisted pairs
Pair lay length held to tight tolerance on 6 in-house twisting lines.
Spline separator (the Cat6 signature)
Plastic cross isolates the four pairs - reduces NEXT and unlocks 250MHz.
Optional foil / braid shield (FTP, SFTP)
For EMI-heavy runs; UTP omits this for clean office environments.
PVC or LSZH outer jacket
CPR EN 50575 rated for EU public-building installations.

Cat6 LAN Cable - Full Datasheet
Cat6 LAN cable with central cross separator, delivering stable high-speed network transmission for indoor LAN installations.
| Product Name | Cat6 Lan Cable |
|---|---|
| AWG | 23AWG or custom |
| Conductor Material | CU / CCA |
| Shield | UTP / FTP / SFTP |
| Jacket Material | 1. PVC Jacket for Cat6 indoor cable 2. PE Single jacket for Cat6 outdoor cable 3. PVC + PE double jacket Cat6 outdoor cable |
| Color | Different color is available |
| Operating Temperature | -20 °C - +75 °C |
| Certification | CE/ROHS/ISO9001 |
| Fire Rating | CMP/CMR/CM/CMG/CMX |
| Application | PC/ADSL/Network Module Plate/Wall Socket/etc |
| Package | 1000ft 305m per roll,or custom |
| Marking On Jacket | Custom |
2.Nominal Velocity of Propagation(NVP):CMX,CM,CMR,LSZH 69%,CMP 72%
3.Maximum Mutual Capacitance:5.6nF/100m
4.Maximum Capacitance Unbalance:330pF/100m
5.Maximum DC Resistance:7.5Ω/100m
6.Maximum Resistance Unbalance:3%
7.Maximum Propagation Delay Skew:30ns/100m
8.Maximum Propagation Delay:536ns/100m@100MHz
9.Minimum Bending radius: 10×Overall Diameter
10.Voltage Rating:80V rms
11.Maximum Pulling Load: 80N
12.Flame Retardant: IEC 60332-1(FRPVC&LSZH Jacket); IEC 60332-1; IEC 60332-3C(LSFROH Jacket)
| Frequency MHz | RL ≥dB | Attenuation ≤dB/100m | NEXT ≥dB/100m | PHASE DELAY≤ ns | ELFEXT ≥dB/100m | PS NEXT ≥dB/100m | PS ELFEXT ≥dB/100m |
|
1 |
20.0 |
2.03 |
74.3 |
570 |
67.8 |
72.3 |
64.8 |
|
4 |
23.0 |
3.78 |
65.3 |
552 |
55.7 |
63.3 |
52.8 |
|
8 |
24.5 |
5.32 |
60.8 |
546.73 |
49.7 |
58.8 |
46.7 |
|
10 |
25.0 |
5.95 |
59.3 |
545.38 |
47.8 |
57.3 |
44.8 |
|
16 |
25.0 |
7.55 |
56.2 |
543 |
43.8 |
54.2 |
40.7 |
|
20 |
25.0 |
8.47 |
54.8 |
542.05 |
41.8 |
52.8 |
38.8 |
|
25 |
24.3 |
9.51 |
53.3 |
541.2 |
39.8 |
51.3 |
36.8 |
|
31.25 |
23.6 |
10.67 |
51.9 |
540.44 |
37.9 |
49.9 |
34.9 |
|
62.5 |
21.5 |
15.38 |
47.7 |
538.55 |
31.8 |
45.4 |
28.8 |
|
100 |
20.1 |
19.8 |
44.3 |
537.6 |
27.8 |
42.3 |
24.8 |
|
200 |
18.0 |
28.98 |
39.8 |
536.54 |
21.8 |
37.8 |
18.8 |
|
250 |
17.3 |
32.85 |
38.3 |
536.27 |
19.8 |
36.3 |
16.8 |


Where Network Architects Specify Cat6
Six deployment scenarios where Cat6 hits the cost/performance sweet spot.
Office LAN
Workstations, VoIP, switches. 1Gbps to every desk with 10Gbps uplink headroom to the core.
Campus Backbone
Building-to-building uplinks under 55m. 10Gbps backbone without paying for Cat6A.
Wi-Fi 6 Access Points
Power + data on one cable. 23AWG bare copper carries 802.3at PoE+ to multi-radio APs.
IP Surveillance
High-bitrate IP cameras and NVR uplinks. 10Gbps headroom for multi-stream camera walls.
Small Data Centre
Top-of-rack to aggregation under 55m. 10Gbps server uplinks without Cat6A cost.
Hospitals & Schools
LSZH jacket for CPR-rated public buildings. Low-smoke, zero-halogen in a fire.

The People Who Actually Make Your Cat6
Four engineers from our Haiyan factory explain what they personally check on every Cat6 reel. You deal with the people who run the machines - not a sourcing desk.
⚒
Master Wire-Drawing Tech
23AWG Cat6 needs thicker copper than Cat5e. I draw every rod to diameter on the day it arrives - no overnight oxidation, no batch drift. DC resistance is set on the first metre, not the last.
🔄
Pair Twisting Line Lead
The spline is the Cat6 signature. My line feeds the plastic cross between the four pairs as they close - if the spline drifts, NEXT fails at 250MHz. I hold pair lay length to ±2% on every run.
🛡
Shielding & Sheathing Operator
For FTP and SFTP, I apply the overall foil and pair braid with on-line coverage monitoring. Jacket thickness is verified against spec - CPR-rated LSZH runs get a separate compound setup so the fire rating holds.
🔍
QC Network Analyser Engineer
Every reel passes my Fluke-class network analyser before it ships. I verify NEXT, return loss, DC resistance and hi-pot withstand at 250MHz. Batch samples stay in my cabinet for 3 years - full lot traceability.
Your Brand on a Cat6 Reel
Custom jacket colour, print legend, length, packaging. RJ45 patch cord assemblies on request. NDA-protected private-label SKUs.
RFQ & Feasibility
Send spec, volume, destination. Feasibility, MOQ and pricing within 12 working hours.
Custom Sample
Custom-printed sample in your brand colour for your termination team to validate.
Production & QC
20–25 working days. Progress photos at copper draw, spline insert, sheath, final test.
Test, Pack & Ship
100% electrical test, export packing, docs (CI/PL/B/L/C/O/RoHS). Ships Shanghai/Ningbo.
Hot Tags: cat6 lan cable, China cat6 lan cable manufacturers, suppliers, factory