Red Fire Alarm Cable

Red Fire Alarm Cable

Red fire alarm cable manufactured for building fire alarm signalling systems. Fire resistant, shielded & unshielded types, BS5839 compliant, LSZH available. Contact us for bulk order and custom specifications.
Send Inquiry
Description

Jiaxing Doublewin Cable Co., Ltd. is one of the most reliable manufacturers and suppliers of red fire alarm cable in China. If you're going to wholesale bulk red fire alarm cable made in China, welcome to get pricelist and free sample from our factory. All customized cables are with high quality and competitive price.

 

Red Fire Alarm Cable - Red-Jacketed Fire Alarm Wiring for Instant Circuit Identification
 

Red fire alarm cable is a fire alarm cable with a red outer jacket, the international standard colour for fire alarm circuit identification. The red jacket instantly distinguishes fire alarm wiring from mains, security, data and other low-voltage cables, simplifying installation, inspection and maintenance. Available in 2 to 24 cores with stranded copper conductors, red LSZH fire alarm cable or red PVC fire alarm cable jackets, compliant with BS 5839, NFPA 72 and EN 54. CPR EN 50575 fire performance. As a red fire alarm cable manufacturer, Jiaxing Doublewin Cable Co., Ltd produces these cables in-house in Haiyan, Zhejiang, China and supplies them in bulk worldwide.

red fire alarm cable
 
 
fire detection cable
Reel  Packing
fire alarm wiring cable
Wooden Spool Packing

 

fire survival cable

 

Red fire Alarm cable Characteristics
Product Name Red Fire Alarm Cable
Conductor Material BC or CCA
Number of Cores 2, 3, 4- 24 Cores
Sectional area 0.75mm²/1.0mm²/1.5mm²/2.5mm²/4.0mm²
Insulation Color Red/Black (2-core); BS EN colour code for multi-core
Insulation Material Fire resistance PVC
Shielding PET and Aluminum Foil
Drain Wire Tinned copper
Rip cord Nylon
Jacket color Red (standard); white, orange, custom on request
Jacket Material PVC or LSZH, PH30, PH120
Rated Voltage 300/300 V
Temperature Range -15°C to +70°C (PVC); up to +90°C (LSZH)
Standard EN 50200, IEC 60331,  BS6387  CPR EN 50575
Certification CE ROHS ISO9001

                                            BS5839 fire alarm cable

Shielded Fire Alarm Cable Parameters

 

Conductor  Cross-section(mm2) Conductor Material Insulation Thickness (mm) 1st - Shield 2nd- Drain Wire 3rd - Shield Rip Cord Jacket OD(mm) Operating Max Voltage DC Resistance (Ω/km @ + 20℃)
2*0.75 (Tinned) Bare Copper 0.55 PET Tinned Copper AL/PET Optional 7.3 450/750 Volts ≤23.0
2*1.0 (Tinned) Bare Copper 0.55 PET Tinned Copper AL/PET Optional 7.5
450/750 Volts  
≤21.4
3*1.0 (Tinned) Bare Copper 0.55 PET Tinned Copper AL/PET Optional 7.9 450/750 Volts ≤21.4
4*1.0 (Tinned) Bare Copper 0.55 PET Tinned Copper AL/PET Optional 8.6 450/750 Volts ≤21.4
2*1.25 (Tinned) Bare Copper 0.60 PET Tinned Copper AL/PET Optional 7.8 450/750 Volts ≤19.5
2*1.5 (Tinned) Bare Copper 0.65 PET Tinned Copper AL/PET Optional 7.9 450/750 Volts ≤12.2
3*1.5 (Tinned) Bare Copper 0.65 PET Tinned Copper AL/PET Optional 8.3 450/750 Volts ≤12.2
4*1.5 (Tinned) Bare Copper 0.65 PET Tinned Copper AL/PET Optional 9.0 450/750 Volts ≤12.2
2*2.5 (Tinned) Bare Copper 0.75 PET Tinned Copper AL/PET Optional 8.9 450/750 Volts ≤8.1
3*2.5 (Tinned) Bare Copper 0.75 PET Tinned Copper AL/PET Optional 9.4 450/750 Volts ≤8.1
4*2.5 (Tinned) Bare Copper 0.75 PET Tinned Copper AL/PET Optional 10.3 450/750 Volts ≤8.1
2*4.0 (Tinned) Bare Copper 1.0 PET Tinned Copper AL/PET Optional 10.7 450/750 Volts ≤4.6

                                 BS6387 fire resistant cable                   

Unshielded Fire Alarm Cable Parameters

 

Conductor Nominal Cross-section(mm2) Conductor Material Insulation  thickness (mm) Rip Cord Jacket OD(mm) Operating Max Voltage     DC Resistance       (Ω/km @ + 20℃) 
2*0.75      ( Tinned ) Bare Copper 0.55 Optional 7.3 450/750 Volts ≤23.0
2*1.0 ( Tinned ) Bare Copper 0.55 Optional 7.5 450/750 Volts ≤21.4
3*1.0 ( Tinned ) Bare Copper 0.55 Optional 7.9 450/750 Volts ≤21.4
4*1.0 ( Tinned ) Bare Copper 0.55 Optional 8.6 450/750 Volts ≤21.4
2*1.25 ( Tinned ) Bare Copper 0.60 Optional 7.8 450/750 Volts ≤19.5
2*1.5 ( Tinned ) Bare Copper 0.65 Optional 7.9 450/750 Volts ≤12.2
3*1.5 ( Tinned ) Bare Copper 0.65 Optional 8.3 450/750 Volts ≤12.2
4*1.5 ( Tinned ) Bare Copper 0.65 Optional 9.0 450/750 Volts ≤12.2
2*2.5 ( Tinned ) Bare Copper 0.75 Optional 8.9 450/750 Volts ≤8.1
3*2.5 ( Tinned ) Bare Copper 0.75 Optional 9.4 450/750 Volts ≤8.1
4*2.5 ( Tinned ) Bare Copper 0.75 Optional 10.3 450/750 Volts ≤8.1
2*4.0 ( Tinned ) Bare Copper 1.0 Optional 10.7 450/750 Volts ≤4.6
 

 

Our Fire Alarm cable Display

 

EN50200 fire alarm cable

 

CPR certified fire alarm cable

 

LPCB approved fire alarm cable

 

LSZH fire alarm cable

 

unshielded fire alarm cable

 

solid copper fire alarm cable

 

 

      

 Why Red Fire Alarm Cable - The International Standard for Fire Alarm Identification

In commercial and public buildings, a single conduit can carry dozens of cables - mains power, security, data, voice, lighting control and fire alarm. Without colour identification, electricians and inspectors waste time tracing the right cable, and there is a risk of accidental disconnection. A red jacket fire alarm cable solves this: red is the international standard colour for fire alarm circuits, instantly identifying the cable as life-safety wiring that must not be cut, de-rated or repurposed. Whether you need a red addressable fire alarm cable for an addressable loop or a red conventional fire alarm cable for a zone circuit, the red jacket gives installers and inspectors instant visual confirmation.

Instant Identification

Red jacket separates fire alarm circuits from all other wiring.

01

Code Compliance

BS 5839, NFPA 72, EN 54 all recognise red for fire alarm circuits.

02

Inspection Ready

Inspectors can visually verify fire alarm circuits at a glance.

03

Accident Prevention

Reduces risk of accidental disconnection during renovations.

04

                                                 

                                    Why Red? Fire Alarm Cable Colour Code Requirements by Standard

 

Major fire alarm codes recognise red as the fire alarm circuit identification colour. The table below summarises the requirements:

 

Standard Region Red Jacket Requirement Notes
BS 5839-1 UK Red jacket recommended for fire alarm cables Standard colour code in UK fire detection systems
EN 54
Europe
Red jacket for fire alarm circuit identification Harmonised across EU member states
NFPA 72 USA Red jacket for fire alarm circuits (NEC 760.179) FPL/FPLR cable - red is standard for fire alarm
AS 1670 Australia/NZ Red sheath for fire detection & alarm Standard identification in Oceania
IS 1658 India Red jacket common for fire alarm wiring Standard identification in Oceania
General Practice International Red = fire alarm wiring Standard identification in Oceania

                                                                             

                                                           

                                                                                         

                                                                                              Quality Control & Testing

 

Every reel is 100% tested before shipment. For multi core fire alarm cable, we test conductor resistance per IEC 60228 on every core, insulation resistance between every pair of cores, and high-voltage withstand between all cores and the sheath. Shield continuity is verified on shielded versions. A sample of each batch is retained for full traceability. Third-party inspection (SGS, BV, TÜV) welcome.

stranded fire alarm cable

Conductor Resistance

IEC 60228 on every core - critical for loop accuracy.

silicone fire resistant alarm cable

Core-to-Core Insulation

Resistance tested between every core pair.

8 core fire alarm cable

Batch Traceability

Sample retained per lot.

 
Typical Applications
 

Suitable for fire alarm signalling wiring in residential, commercial and public buildings.

Commercial Buildings

Offices, retail, hotels - red jacket for code compliance.

 

Public Buildings

Schools, hospitals, government - red LSZH standard.

 

Residential Blocks

Apartments, HMOs - red PVC for cost-effective work.

Industrial Plants      Factories, warehouses - red for safety-critical visibility.

Heritage & Listed    Red jacket for easy identification during refurbishment.

building fire alarm cable
Building Fire Alarm Wiring
fire alarm system cable
Fire Detector & Control Panel Connection

 


Frequently Asked Questions

 

Q:What is red fire alarm cable?

A:Red fire alarm cable is a fire alarm cable with a red outer jacket - the international standard colour for fire alarm circuit identification. The red jacket instantly distinguishes fire alarm wiring from mains, security, data and other low-voltage cables, simplifying installation, inspection and maintenance.

Q: Why is fire alarm cable red?

A:Red is the recognised colour for fire alarm circuits in major codes including BS 5839 (UK), NFPA 72 (US), EN 54 (Europe) and AS 1670 (Australia/NZ). The red jacket allows electricians and inspectors to instantly identify life-safety wiring that must not be cut or repurposed.

Q: Is red fire alarm cable required by code?

A: In most regions, red is the recommended or required colour for fire alarm circuit identification. BS 5839-1 recommends red, NFPA 72 / NEC 760 specifies red for fire alarm cable (FPL), and EN 54 recognises red for fire alarm circuits. Check your local code for exact requirements.

Q:What is the difference between red LSZH and red PVC fire alarm cable?

A:Red LSZH fire alarm cable has a low-smoke, zero-halogen jacket - required for public buildings, tunnels and confined spaces because it emits less toxic smoke in a fire. Red PVC fire alarm cable is more cost-effective and used for residential and general commercial work where smoke toxicity is less critical.

Q: Can I get a custom red shade?

A: Yes. Standard is RAL 3020 (bright red). We can also supply RAL 2002 (vermilion), RAL 3001 (signal red), RAL 2008 (orange-red) or match a specific RAL reference for your project or brand standard.

Q:What print is on the red jacket?

A:Standard print includes "FIRE ALARM CABLE", conductor size, voltage rating, standard reference (e.g. BS 5839, CPR class) and sequential metre marking. For OEM orders we can add your brand name, batch code and logo.

 

 

 

 